Zetron Mic600 Fixed Gas Detector 6 in 1 for Carbon Monoxide, Chlorine, Nitrogen Dioxide and Phosgene Gas Leakage Detector
Contact Supplier
Product Highlights
- IP66 Protection Level: Robust IP66 rating ensures reliable operation in harsh industrial environments.
- HD Color Display: 2.5-inch HD color screen displays real-time data, curves, and alarm status.
- Extensive Data Storage: Standard 100,000 entries storage with optional SD card support.
- Flexible Communication: Supports 4-20mA, RS485 Modbus-RTU, and wireless/network transmission.
- Comprehensive Certifications: FCC, CE, RoHS, and ATEX certified for global safety compliance.
- Customizable Sensor Life: Electrochemical sensors last 2-3 years; Infrared sensors last 5-10 years.
Product Attributes
- Customization
- Available
- After-sales Service
- We Provide After Sale Services.
- Warranty
- 1 Year
- Model NO.
- MIC600
- Brand
- Zetron
- Customized
- Customized
- Portable
- Non Portable
- Certification
- FCC, CE, RoHS, Atex
- Gas
- Can Be Customized
- Type
- Thermal Conductivity Gas Analyzer
- Detecting Gas
- Combustible Gas/H2s/Co/O2
- Certificate
- ISO9001 Cnex CE Atex
- Response Time
- T90<20s
- Sampling Method
- Depending on Gas Nature
- Degree of Protection
- IP67
- Range
- 0 - 10/100/1000ppm/1%/25%
- Working Voltage
- 24V
- Recovery Time
- <30s
- Alarm Type
- Multiple Alarm Mode
- Sensor
- Imported Highly Precise Sensor
- Weight
- 1.78kg
- Accuracy
- 3% F.S Can Be Customized
- Linearity
- 3% F.S Can Be Customized
- Resolution
- 0.01ppm, 0.01%Lel, 0.01%Vol
- Diplay
- 1.7" HD LCD Display
- Transport Package
- Paper Carton
- Specification
- Highly Sensitive Imported Sensor
- Trademark
- Zetron
- Origin
- China
- HS Code
- 902710
- Production Capacity
- 1000/Month
Product Images of Zetron Mic600 Fixed Gas Detector 6 in 1 for Carbon Monoxide, Chlorine, Nitrogen Dioxide and Phosgene Gas Leakage Detector
Find Similar Products
Product Description
ZETRON MIC600 Fixed Gas Detector 6 in 1 for carbon monoxide, chlorine, nitrogen dioxide and phosgene Gas Leakage Detector
The optional high-temperature high-humidity pretreatment system will be possible to detect the smoke gas at the temperature of1300 ºC. The detection for the gases at other temperatures can be customized. Simultaneously display the concentrations of multiple types of gases, repeatedly display the concentration of single-channel gases in large font, and display the realtime curve.2.5-inch high-definition color screen, display the information such as real-time concentration, alarm, time, temperature, humidity, storage, and so on; the menu interface adopted high definition simulation graphics to display the function name of each menu.
Standard configuration is the data storage capacity for 100, 000 entries; SD card storage function is optional configuration, real-time storage and fixed time storage are supported, or only the data of the alarm concentration will be stored; it is supported to use the local host to view, and delete data, and upload the data via RS485 interface to the computer for data analysis or printing.
It is possible for the real-time monitoring via the wired or remote wireless transmission, and network transmission; three-wire system 4 ~ 20mA standard signal and standard bus RS485 (modbus-RTU) simultaneous output; it is compatible with secondary instrument, data acquisition module, PLC,DCS system, and it is possible to drive the related equipment. Data recovery function; in case of mis-operation, it is possible to select partial or full recovery. Multiple alarm modes, and multi-directional and three-dimensional indication alarm states. It includes: 2 sets of relay switch output, sound & light alarm (optional configuration). Alarm types include: concentration alarm, and failure alarm.



|
Type
|
Fixed Gas Detector
|
||||
|
Detection range
|
0~ 10ppm
0~ 20ppm 0~50ppm 0~100ppm Other ranges can be customized |
||||
|
Resolution
|
0.01ppm or 0.001ppm (0 ~ 10 ppm); 0.01ppm (0 ~ 100 ppm),
Other ranges can be customized
|
||||
|
Detection principle
|
Electrochemical, infrared, thermal conductivity, PID photoionization, and so on. Depending on the type of gas, range, field environment and user demand, Sensor can be customized
|
||||
|
Sensor service life
|
Electrochemical principle: 2 ~ 3 years; Infrared principle: 5 ~ 10 years;
Thermal conductivity: 5 years |
||||
|
Allowable error
|
≤±2% F.S (other or higher precision levels can be customized)
|
||||
|
Linearity
|
≤±2%
|
Repeatability
|
≤±2%
|
Uncertainty
|
≤±2%
|
|
Response time
|
T90≤30 seconds
|
Recovery time
|
≤30 seconds
|
||
|
Working environment
|
Temperature: -40 ºC ~ + 70 ºC, humidity: ≤10 ~ 95% RH (regular)
|
||||
|
Working voltage
|
12 ~ 30VDC direct current the standard power supply for a single equipment is 24V, DC stabilized voltage switching power supply of 1A or greater than 1A
|
||||
|
Power supply reference
|
24V, 2.1A is possible to drive 40 units of toxic gas detector, or 15 units of flammable, infrared gas detector.
|
||||
|
Working method
|
Fixed type installation, online detection, diffusion type measurement
|
||||
|
Protection level
|
IP66
|
||||
|
Explosion-proof mark
|
ExdIICT6, certificate number: CNEx15.1283
|
||||
|
Exterior dimensions
|
210×170×85mm (L×H×W)
|
||||
|
Weight
|
1.8 Kg
|
||||
|
Standard accessories
|