• Ms400 - 4 in 1 Built-in Pump USB/RS485 High Sensitivity Self Test Hydrogen Sulfide/H2s Gas Monitor Portable
  • Ms400 - 4 in 1 Built-in Pump USB/RS485 High Sensitivity Self Test Hydrogen Sulfide/H2s Gas Monitor Portable
  • Ms400 - 4 in 1 Built-in Pump USB/RS485 High Sensitivity Self Test Hydrogen Sulfide/H2s Gas Monitor Portable
  • Ms400 - 4 in 1 Built-in Pump USB/RS485 High Sensitivity Self Test Hydrogen Sulfide/H2s Gas Monitor Portable
  • Ms400 - 4 in 1 Built-in Pump USB/RS485 High Sensitivity Self Test Hydrogen Sulfide/H2s Gas Monitor Portable
  • Ms400 - 4 in 1 Built-in Pump USB/RS485 High Sensitivity Self Test Hydrogen Sulfide/H2s Gas Monitor Portable

Ms400 - 4 in 1 Built-in Pump USB/RS485 High Sensitivity Self Test Hydrogen Sulfide/H2s Gas Monitor Portable

After-sales Service: We Provide After Sale Services.
Warranty: 1 Year
Brand: Zetron
Customized: Customized
Portable: Portable
Certification: FCC, CE, RoHS
Customization:
Gold Member Since 2024

Suppliers with verified business licenses

Beijing, China
to see all verified strength labels (15)
  • Overview
  • Specification
  • DETECTABLE GASES
  • Company Profile
Overview

Basic Info.

Model NO.
Ms400
Gas
4 Types of Gasses Can Be Customized
Type
Electrochemical Catalytic Infrared and Pid
Sensor
Imported Highly Sensitive Sensor
Alarm
Sound+Vibration+Light
Degree of Protection
IP65
Response Time
T90<20s
Sampling Method
Depending on Gas Properties
Working Temperature
Standard -20~50c (Can Be Customized)
Humidity
<95%Rh
Display
HD Color LCD Display
Measuring Range
0-1000ppm 0-100% Vol 0-100 % Lel
Resolution
0.01ppm, 0.01% Vol, 0.01% Lel
Sensor Life
2 ~ 10 Year (Can Be Customized)
Power Supply
3.7VDC, 4500mA High Capacity Rechargeable Polymer
Weight
300g
Explosion-Proof Mark
Exia II CT6
Exterior Dimensions
160×70×28mm (L×w×h)
Transport Package
Paper Carton
Specification
Built in Suction Pump 4 in 1 Multi Gas Detector
Trademark
Zetron
Origin
China
HS Code
902710
Production Capacity
10000/Month

Product Description

MS400 - 4 in 1 Built-in Pump USB/RS485 High Sensitivity Self Test Hydrogen Sulfide/H2S Gas Monitor Portable

MS400 Series Portable Composite Gas Detector can be used in: mobile rapid and accurate detection of a variety of gas concentration and measurement of environmental temperature and humidity, if the measurement exceeded the limit value, the alarm will sound. It adopted advanced electric circuit design, mature kernel algorithm processing, unique external appearance design, had achieved a number of patents about the software works, external appearance, and so on. It is possible to simultaneously detect 1 ~ 4 types of gases, and the units can be switched freely. The types for detection are more than 500 types.
 
MS400 is unparalleled in its versatility, capability and overall value. It's adopted water-resistant line of portable gas detectors has transformed the market with its matchless array of features. Continuously monitoring and displaying concentrations of up to 4 gases, the compact and lightweight MS400 was designed and engineered with an extensive host of applications in mind.
 
Ms400 - 4 in 1 Built-in Pump USB/RS485 High Sensitivity Self Test Hydrogen Sulfide/H2s Gas Monitor Portable
 
 
Specification
Gases to be detected Arbitrary combination of 1 ~ 4 types of gases such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on. Optional configuration: temperature and humidity measurements.
Application scenarios All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.
Detection range 0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 100%LEL, 20%, 50%, 100%Vol, can be selected; and other ranges can be customized.
Resolution 0.01ppm or 0.001ppm (0 ~ 10 ppm);
0.01ppm (0 ~ 100 ppm),
0.1ppm (0 ~ 1000 ppm),
1ppm (0 ~ 10000 ppm or more),
0.01 mg/l (0 ~ 200 mg/l),
0.1% LEL,
0.01%LEL
0.001% Vol
Detection principle Electrochemical, catalytic combustion, infrared, thermal conductivity,PID photoionization, and so on. Depending on the type of gas, range, field environment and user demand.
Sensor service life Electrochemical principle: 2 ~ 3 years; Oxygen gas: 2 years or 6 years can be selected; Infrared principle: 5 ~ 10 years; Catalytic combustion: 3 years; Thermal conductivity: 5 years; PID photoionization: 2 ~ 3 years.
Allowable error ≤±3% F.S (other precision levels can be customized)
Working environment Temperature: -40 ºC ~ + 70 ºC, humidity: ≤10 ~ 95% RH, and built-in filters can be used in high humidity or high dust environment.
DETECTABLE GASES
Detected Gases
Range
Minimum Reading
Detected Gases
Range
Minimum Reading
VOCs(VOC)
0-20ppm
0.01ppm
Ethylene oxide (ETO)
0- 100%LEL
0. 1%LEL
VOCs(VOC)
0-200ppm
0. 1ppm
Phosgene(COCL2)
0- 1ppm
0.001ppm
VOCs(VOC)
0-2000ppm
1ppm
Phosgene(COCL2)
0- 10ppm
0.01ppm
VOCs(VOC)
0- 10000ppm
1ppm
Silane(SiH4)
0- 1ppm
0.001ppm
Gas (EX)
0- 1000ppm
1ppm
Silane(SiH4)
0-50ppm
0.01ppm
Gas (EX)
0- 100%LEL
0. 1%LEL
Fluorine gas (F2)
0- 1ppm
0.001ppm
Gas (EX)
0- 100%VOL
0.01%VOL
Fluorine gas (F2)
0- 10ppm
0.001ppm
Methane (CH4)
0- 100%LEL
0. 1%LEL
Fluorine gas(F2)
0- 100ppm
0.01ppm
Methane (CH4)
0- 100%VOL
0.01%VOL
Hydrogen Fluoride (HF)
0- 10ppm
0.01ppm
Oxygen (O2)
0-30%VOL
0.01%VOL
Hydrogen Fluoride (HF)
0-50ppm
0.01ppm
Oxygen (O2)
0- 100%VOL
0.01%VOL
Hydrogen Bromide(HBr)
0-50ppm
0.01ppm
Carbon Monoxide (CO)
0- 100ppm
0.01ppm
Ethylborane(B2H6)
0- 10ppm
0.001ppm
Carbon Monoxide (CO)
0- 1000ppm
0. 1ppm
Arsine(AsH3)
0- 1ppm
0.001ppm
Carbon Monoxide (CO)
0-2000ppm
1ppm
Arsine(AsH3)
0- 10ppm
0.001ppm
Carbon Monoxide (CO)
0-5000ppm
1ppm
Germanium(GeH4)
0- 1ppm
0.001ppm
Carbon Monoxide (CO)
0- 10000ppm
1ppm
Germanium(GeH4)
0- 10ppm
0.001ppm
Carbon dioxide (CO2)
0-5000ppm
1ppm
Germanium(GeH4)
0-50ppm
0.01ppm
Carbon dioxide (CO2)
0-50000ppm
1ppm
Hydrazine, hydrazine hydrazide (N2H4)
0- 1ppm
0.001ppm
Carbon dioxide (CO2)
0-5%VOL
0.01%VOL
Hydrazine, hydrazine hydrazide (N2H4)
0-300ppm
0. 1ppm
Carbon dioxide (CO2)
0-20%VOL
0.01%VOL
Tetrahydrothiophene (THT)
0-50mg/m3
0.01 mg/m3
Carbon dioxide (CO2)
0- 100%VOL
0.01%VOL
Bromine (Br2)
0- 10ppm
0.01ppm
Formaldehyde (CH2O)
0- 10ppm
0.01ppm
Bromine gas (Br2)
0-50ppm
0.01ppm
Formaldehyde (CH2O)
0-50ppm
0.01ppm
Sulfur dioxide (SO2)
0-20ppm
0.01ppm
Formaldehyde (CH2O)
0- 100ppm
0.01ppm
Sulfur dioxide (SO2)
0- 100ppm
0.01ppm
Formaldehyde (CH2O)
0- 1000ppm
1ppm
Sulfur Dioxide(SO2)
0- 1000ppm
0. 1ppm
Ozone (O3)
0- 1ppm
0.001ppm
Sulfur dioxide (SO2)
0-5000ppm
1ppm
Ozone (O3)
0- 10ppm
0.01ppm
Nitric oxide (NO)
0-20ppm
0.01ppm
Ozone (O3)
0- 100ppm
0.01ppm
Nitric Oxide (NO)
0- 100ppm
0.01ppm
Ozone (O3)
0-2000ppm
1ppm
Nitric Oxide (NO)
0- 1000ppm
0. 1ppm
Hydrogen Sulfide (H2S)
0- 10ppm
0.01ppm
Nitric Oxide (NO)
0-5000ppm
1ppm
Hydrogen sulfide (H2S)
0- 100ppm
0.01ppm
Nitrogen Dioxide (NO2)
0-20ppm
0.01ppm
Hydrogen sulfide (H2S)
0-500ppm
0. 1ppm
Nitrogen dioxide
0- 100ppm
0.01ppm
Hydrogen sulfide (H2S)
0-2000ppm
1ppm
Nitrogen dioxide
0- 1000ppm
0. 1ppm
Hydrogen Cyanide(HCN)
0- 100ppm
0.01ppm
Nitrogen Dioxide (NO2)
0-2000ppm
1ppm
Hydrogen Chloride(HCL)
0-20ppm
0.01ppm
Nitrogen Oxides (NOX)
0- 100ppm
0.01ppm
Hydrogen chloride (HCL)
0-200ppm
0. 1ppm
Nitrogen Oxides (NOX)
0-500ppm
0. 1ppm
Phosphine (PH3)
0-5 ppm
0.001ppm
Nitrogen oxides (NOX)
0-2000ppm
1ppm
Phosphine (PH3)
0-20 ppm
0.01ppm
Chlorine (CL2)
0-20ppm
0.01ppm
Phosphine(PH3)
0-2000 ppm
1ppm
Chlorine (CL2)
0-200ppm
0. 1ppm
Chlorine dioxide (CLO2)
0- 1ppm
0.001ppm
Ammonia (NH3)
0- 10ppm
0.01ppm
Chlorine dioxide (CLO2)
0- 10ppm
0.01ppm
Ammonia (NH3)
0- 100ppm
0.01ppm
Chlorine dioxide (CLO2)
0- 100ppm
0.01ppm
Ammonia(NH3)
0- 1000ppm
0. 1ppm
Ethylene oxide (ETO)
0- 100ppm
0.01ppm
Ammonia gas (NH3)
0-5000ppm
1ppm
Ethylene oxide (ETO)
0- 1000ppm
0. 1ppm
Ammonia(NH3)
0- 100%LEL
0. 1%LEL

Ms400 - 4 in 1 Built-in Pump USB/RS485 High Sensitivity Self Test Hydrogen Sulfide/H2s Gas Monitor PortableMs400 - 4 in 1 Built-in Pump USB/RS485 High Sensitivity Self Test Hydrogen Sulfide/H2s Gas Monitor Portable

Company Profile
 

Beijing Zetron Technology Co., Ltd, With 20 years combined experience, Zetron develops, manufacture and market a complete range of gas detection equipment to protect people from hazardous conditions in the industry, research and commercial applications. Today Zetron is in providing gas detection equipment, services and solutions to keep your personnel and plant safe. Our complete product range includes portable gas detector, fixed detection systems, landfill gas analyzer, remote laser methane gas detector, as well as air quality monitoring systems.
As part of our focus on quality, Zetron is ISO9001:2005 and SGS certified and our products have acquired the CE, RoHS, FCC, and ATEX certifications.
So far, we have customers/buyers from over 20 countries/regions like Bulgaria, Brazil, Canada, China, Colombia, Germany, Iraq, Japan, Philippines, Russian Federation, Singapore, Taiwan, Thailand, Uruguay, United States, Ukraine, Vietnam, etc.
The list of countries still expanding.....

We are committed to become the International Well Know Provider to provide similar or better alternative, original merchandises & service to meet customers' needs, requirements and solutions.
Every customer is important to us and we strive to satisfy all our Customers needs and expectations.

Ms400 - 4 in 1 Built-in Pump USB/RS485 High Sensitivity Self Test Hydrogen Sulfide/H2s Gas Monitor Portable

Ms400 - 4 in 1 Built-in Pump USB/RS485 High Sensitivity Self Test Hydrogen Sulfide/H2s Gas Monitor Portable
Ms400 - 4 in 1 Built-in Pump USB/RS485 High Sensitivity Self Test Hydrogen Sulfide/H2s Gas Monitor Portable
 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now