Zetron Th-1000 Continuous Emission Monitoring System

Product Details
Customization: Available
After-sales Service: 1 Year
Warranty: 1 Year
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 4 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (15)
  • Zetron Th-1000 Continuous Emission Monitoring System
  • Zetron Th-1000 Continuous Emission Monitoring System
Find Similar Products
  • Overview
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
TH-1000
Brand
Mpower
Customized
Customized
Portable
Portable
Certification
FCC, CE, RoHS
Gas
Toxic Gases, Oxygen, Carbon Dioxide, Flammable and
Type
Thermal Conductivity Gas Analyzer
External Size
400&;180&;600mm(L×h×w)
Weight
1.8kg(Probes)
Linearity
-2%~+2%
Repeatability
-2%~+2%
Uncertainty
-2%~+2%
Recovery Time
30 Second
Transport Package
Paper Carton
Specification
400× 180× 600mm(L× H× W)
Trademark
Zetron
Origin
China
HS Code
9027100090

Packaging & Delivery

Package Size
45.00cm * 20.00cm * 65.00cm
Package Gross Weight
2.500kg

Product Description

TH-1000  Continuous Emission Monitoring System

The on-line monitoring and pretreatment system is applied to 24-hour continuous on-line monitoring of on-site gas concentration. It is equipped with 7-inch high-definition color screen to display on-site concentration, over standard on-site audible and visual alarm (optional), remote signal GPRS, DTU, Lora and other transmission. The gas sensor of international famous brand is adopted. The main detection principles include: gas sensor based on the principles of electrochemistry, infrared, catalytic combustion, thermal conductivity, PID photo ion, etc.
 

 
Detailed Photos

Zetron Th-1000 Continuous Emission Monitoring System

Product Parameters
Detecting gas Toxic gases, oxygen, carbon dioxide, flammable and explosive gases, TVOC, etc.
Applications Petroleum, chemical, pharmaceutical, environmental protection, gas distribution, storage, flue gas analysis, air treatment and all other occasions that require fixed installation and online detection of gas concentration.
Testing range 0~1,10,100,1000,5000,50000,100000ppm,200ml/L,100%LEL,20%,50%,99.999%,100%Vol Optional,Other ranges can be customized
Resolution 0.01ppm or 0.001ppm(0~10 ppm);0.01ppm(0~100 ppm),0.1ppm(0~1000 ppm),1ppm(0more than 1000 ppm),0.01ml/L(0~200%ml/L),0.1%LEL,0.01%,0.001%Vol.
Detection principle Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, etc., depending on gas type, range, site environment and user requirements.
Sensor life Electrochemical principle 2 to 3 years, oxygen 2 years or 6 years optional, infrared principle 5 to 10 years, catalytic combustion 3 years, thermal conductivity 5 years.
Detection accuracy ≤±3%F.S  (Higher precision can be customized)
Linearity ≤±2%
Repeatability ≤±2%
Uncertainty ≤±2%
Recovery time 3second
Response time T902second
Signal Output Bus system RS485 (RTU), three (four) wire system 4~20mA, optional: 0~20mA, 1~5V, 0~5V, 0~10V, wireless transmission, network transmission, SMS alarm.
Working Environment Temperature:-40ºC~+70ºC,Humidity:10~95%RH (General)Non-condensing occasions in the use of condensing occasions must be custom-made or specify the use of environment when ordering
Display On-site 1.7" HD color screen display, optional on-site no display, or optional MIC2000 controller remote display, control, alarm
Working Voltage 12 to 36VDC, 24V, 1A or more than 1A DC regulated switching power supply as standard for a single device
Power 24V, 2.1A switching power supply can drive 40 toxic gas detectors, or 15 combustible and infrared gas detectors
Operation mode Fixed installation, online detection, diffusion measurement; optional pipeline, circulation, pump suction measurement
Installation method Pipeline type, wall-mounted type. The working pressure of pipeline type is ±30% of atmospheric pressure, beyond the range need to reduce the pressure treatment.
Alarm method Default 1 way, optional 2 way passive contact (dry node) output, three level alarm, alarm point can be set. Live sound and light alarm (optional)
Connection Cable 4 ~ 20mA selected three-core shielded cable, RS485 selected four-core, the distance of more than 1000 meters when the single wire diameter ≥ 1.5mm; shielding layer to earth.
Protection level IP65 (Probes)
Explosion-proof type Explosion-proof type (Probes)
Explosion-proof signs Exd2CT6(Probes)
Execution Standards GB15322.1-2003
GB 3836.1-2010 
GB 3836.2-2010 
External size 400×180×600mm(L×H×W)
Weight 1.8Kg(Probes)
Standard Accessories Instruction manual, certificate of conformity, warranty card, outer box packaging box
Options One-piece sound and light alarm, split sound and light alarm, 24V DC regulated power supply, accessories for computer monitoring: free host software, RS485/RS232 converter, USB/RS232 conversion cable for laptops without RS232 interface, and TCP/IP converter for network transmission.
Wireless transmission Optional function, you can wirelessly transmit data to cell phones, remote monitoring centers, monitoring computers and other monitoring equipment, using the computer on the computer, data analysis, storage, printing and other functions
Pretreatment system Optional: Normal temperature and high humidity pretreatment system, high temperature and high humidity pretreatment system, high temperature and high humidity and high dust pretreatment system
Mounting accessories Optional: wall mounting bracket, mounting buckle fixed on the pipeline (four or six branch pipes), stainless steel threaded welding seat or flange for pipeline installation (pipe or flange size shall be indicated, such as DN50, DN15...) Rain cover, 24VDC or 220ac sampling pump (sampling distance 10m), vacuum pump (sampling distance greater than 40m), 24V switching power supply, pressure reducing valve and flowmeter.
 
Certifications


Zetron Th-1000 Continuous Emission Monitoring System

 

Company Profile

Beijing Zetron Technology Co., Ltd, formerly Beijing Senre Technology Co., Ltd was founded in 2011, located in Beijing with convenient transportation access. We have almost 12 years experience in the retail, import and export of gas detection and monitoring equipment.

This experience has enabled us to form an organisation based on knowledge and expertise and have allowed us to supply a range of gas detectors and monitors that are tailored to our customers needs and budgets. Our aim is to provide the best values products with high quality and style.To provide the new affordable and complete service for gas detection needs for the industrial, engineering and shipping market and our friendly staff are here to help with advice and prices. So far, we have customers/buyers from over 20 countries/regions like Bulgaria, Brazil, Canada, China, Colombia, Germany, Iraq, Japan, Philippines, Russian Federation, Singapore, Taiwan, Thailand, Uruguay, United States, Ukraine, Vietnam, etc.
Zetron Th-1000 Continuous Emission Monitoring System
Zetron Th-1000 Continuous Emission Monitoring System

 
The list of countries still expanding.....!!
We are committed to become the International Well Know Provider to provide similar or better alternative, original merchandises & service to meet customers' needs, requirements and solutions.
 
Every customer is important to us and we strive to satisfy all our Customers needs and expectations.
Local and International Distributors, Dealers and Resellers are Welcomed! Please contact us at the homepage.
FAQ

Zetron Th-1000 Continuous Emission Monitoring System



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier