Th2000 Gas Pretreatment System with Dehumidification and Filtration for Gas Analyzers

Product Details
Customization: Available
After-sales Service: 1 Year
Warranty: 1 Year
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 4 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (15)
  • Th2000 Gas Pretreatment System with Dehumidification and Filtration for Gas Analyzers
  • Th2000 Gas Pretreatment System with Dehumidification and Filtration for Gas Analyzers
  • Th2000 Gas Pretreatment System with Dehumidification and Filtration for Gas Analyzers
  • Th2000 Gas Pretreatment System with Dehumidification and Filtration for Gas Analyzers
Find Similar Products
  • Overview
  • Product Description
  • Product Feature
  • Product Parameters
  • Detailed Photos
  • Application
  • Certifications
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
TH-2000
Brand
Zetron
Customized
Customized
Portable
Portable
Certification
CE, RoHS
Gas
Customized
Type
Alarm Controller
Power Supply
AC220V±15%, 50Hz±1%
Input Signal
RS-485/ 4-20mA
Display
8 Inch TFT LCD Touch Screen
Alarm Mode
Audible, Visual
Installation Mode
Wall-Mounted
Suitable Gas Detector
Mic100 Fixed Gas Detector with RS485 Signal Output
Protection Grade
IP54
Weight
About 3.6kg
Transport Package
Carton
Specification
400mm*280mm*80mm
Trademark
Zetron
Origin
China
HS Code
9027100090
Production Capacity
1000 Set/Sets Per Month

Packaging & Delivery

Package Size
40.00cm * 20.00cm * 60.00cm
Package Gross Weight
5.000kg

Product Description

TH2000 Gas Pretreatment System with Dehumidification and Filtration for Gas Analyzers

Product Description

Differential Optical Absorption Spectroscopy or DOAS, is based on the principle of measuring the differential absorption of the incoming signal in the wavelength region of interest after it has passed through a gas
medium.  It uses a broadband light source and the measurement is made over a large wavelength range
(like FTIR and NDIR, and unlike TDL that uses a very narrow wavelength range).  In general, overlap of
absorption features of several gases is observed.  This requires the use of multiple regression methods of     analysis. The concentrations of a gases are calculated by comparing the absorption signals with their stored reference signals.  As in any broadband measurement technique, interference from other gases must be
taken into account and corrected for to improve accuracy of measurement.  This requires a prior knowledge of the gas composition before the final measurements can be made.

DOAS is capable of measuring more than one species which either absorb in the same wavelength region (continuous monitoring of the species; e.g., NO, NH3, SO2 etc.) or in different wavelength regions (time-    shared monitoring of the species; e.g., NO, NO2, HCHO etc.).
Th2000 Gas Pretreatment System with Dehumidification and Filtration for Gas Analyzers

 

Product Feature

High Measurement Accuracy
   The minimum detection limit of SO2, NO, NO2 can be 1mg/m3 ( 15 m optical path)
    Ultraviolet has no moisture absorption: undisturbed by moisture and dust.
    No cross interference between the gas being measured
    NO and NO2 can be measured at the same time, dispense with converter.
    Low detection limit.
High Reliability
    DOAS + PLS technology, small amount of zero drift and span drift
    Modular design
•   Available version with external UV bench for use with toxic or corrosive gases.
•    No optical moving parts and no vibration influence.
   Strong gas cell, low cost.
   Spectrum automatic adjustment technology, long free maintenance cycle
    Light source adopts the pulse source; the service life is 10 years
European Compliance
    Low Voltage Directive 2014/35/EU
    EMC Directive 2014/30/EU

Product Parameters

 
Model Multi-Flue-S (standard) | Multi-Flue-LE (Low Emission) | Multi-
Flue-ULE (UltraLow Emission)
Measuring Principle UV DOAS + PLS (all the gas); Electrochemical (O2); Laser (CO)
Linearity  ±1.5% FS
Repeatability  ±0.5% FS
Zero & Span Drift  ±2% FS
Response time (T90) < 10 sec. | < 30 sec. | < 30 sec.
Working Temperature -10.C  .+40.C
Warmup Time No pre-heating | Approx. 10 min.
Sample Gas Interface Ø6 Bi-lok
Atmospheric pressure effect: ± 0.13% of reading per mmHg.
Sample Gas Flow 0.5…2 l/min., Fluctuation < 25%
Sample Gas Pressure The current environmental pressure ±0.1 Bar
Sample Temperature 0.C  .+50.C
Sample Gas Humidity Non condensation (under sample temperature)
4-20 mA Input Interface 3 x configurable, max. load 100 Ω
4-20 mA Output Interface 5 x configurable, max. load < 800 Ω
Switch Input Interface 6 x configurable
Relay Output Interface 14 x configurable, 30 VDC, 2A
Communication Interface 1 x RS232, 1x RS 485 (ModBus)
Installation Rack 19"
Supply 100...240 VAC
Power ~ 100W | ~ 200W
Outline Dimensions 132(H) x 483(W) x 378(D) mm | 177(H) x 483(W) x 412(D) mm | 177(H) x 483(W) x 412(D) mm
Weight: ~ 10 Kg. | ~ 12 Kg.

Detailed Photos

Th2000 Gas Pretreatment System with Dehumidification and Filtration for Gas Analyzers

Application

The TH-2000 Gas detection controller used to connect with the fixed gas detector and the related equipment in industrial scene, such as petroleum refinery, chemical plants, LPG stations, boiler rooms, gas stations, paint spray booths, metallurgy, mining, fire, environmental protection, etc.

Certifications

The products have passed ISO9001 quality management system certification, IS014001 environmental management system certification,CCEP China environmental protection products certification and obtained the corresponding product explosion-proof certificate, CPA type approval certificate, CMC measurement license, appearance brick certificate, software copyright registration certificate, etc.

Th2000 Gas Pretreatment System with Dehumidification and Filtration for Gas Analyzers

 

Company Profile

Beijing Zetron Technology Co., Ltd, formerly Beijing Senre Technology Co., Ltd was founded in 2011, located in Beijing with convenient transportation access. We have almost 12 years experience in the retail, import and export of gas detection and monitoring equipment.

This experience has enabled us to form an organisation based on knowledge and expertise and have allowed us to supply a range of gas detectors and monitors that are tailored to our customers needs and budgets. Our aim is to provide the best values products with high quality and style.To provide the new affordable and complete service for gas detection needs for the industrial, engineering and shipping market and our friendly staff are here to help with advice and prices. So far, we have customers/buyers from over 20 countries/regions like Bulgaria, Brazil, Canada, China, Colombia, Germany, Iraq, Japan, Philippines, Russian Federation, Singapore, Taiwan, Thailand, Uruguay, United States, Ukraine, Vietnam, etc.
Th2000 Gas Pretreatment System with Dehumidification and Filtration for Gas Analyzers
The list of countries still expanding.....!!
We are committed to become the International Well Know Provider to provide similar or better alternative, original merchandises & service to meet customers' needs, requirements and solutions.
 
Every customer is important to us and we strive to satisfy all our Customers needs and expectations.
Local and International Distributors, Dealers and Resellers are Welcomed! Please contact us at the homepage.
FAQ

Th2000 Gas Pretreatment System with Dehumidification and Filtration for Gas Analyzers

 















 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier