Zetron OPC-L3 Desktop Laser Oil Particle Counter Machine

Product Details
Customization: Available
Type: Semiconductor Laser
Sample Feeding: High-Pressure Syringe Pump Sampling
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 4 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (15)
  • Zetron OPC-L3 Desktop Laser Oil Particle Counter Machine
  • Zetron OPC-L3 Desktop Laser Oil Particle Counter Machine
  • Zetron OPC-L3 Desktop Laser Oil Particle Counter Machine
  • Zetron OPC-L3 Desktop Laser Oil Particle Counter Machine
  • Zetron OPC-L3 Desktop Laser Oil Particle Counter Machine
  • Zetron OPC-L3 Desktop Laser Oil Particle Counter Machine
Find Similar Products
  • Overview
  • Product Description
  • Product Feature
  • Product Parameters
  • Application
  • Company Profile
Overview

Basic Info.

Model NO.
OPC-L3
Principle
Photoresist (Shading) Counting Principle
Flow Rate
5 -80ml/Min
Range
0.8μm-600μm
Channels
64 Channels (Editable Channels), The Particle Size
Sample Test Viscosity
≤650cst
Sampling Volume
0.2~6000ml, Interval 0.1ml
Sampling Accuracy
Better Than ±0.5%
Sampling Speed
5 ~80ml/Min
Test Sample Temperature
0ºC-80ºC
Power Supply
110~245V AC, 50/60Hz, 70W
Host Size
340mm×310mm×730mm
Main Unit Net Weight
22 Kg
Air Pump Net Weight
5.5kg
Transport Package
Carton
Specification
340mm× 310mm× 730mm, 22kg
Trademark
zetron
Origin
China
HS Code
9031809090
Production Capacity
1000 Piece/Pieces Per Month

Product Description

 
OPC-L3 Oil Particle Counter
 

Product Description

OPC-L3 oil particle counter is an upgraded product on the basis of OPC-L2, which is based on GB/T 18854-2002 (ISO11171-1999) and other standards.

Adopting the counting principle of photo-resistive (shading) method, it fully conforms to the corresponding national standard and international standard.

It can provide fast, accurate, reliable and repeatable test results and complete pollution monitoring and analysis report.
Zetron OPC-L3 Desktop Laser Oil Particle Counter Machine

Product Feature

Upgrade Function
· Laboratory model with Win10 or higher
· The operating system is extremely compatible and modernized, and can be installed on tablets, laptops or desktop computers
· More than a dozen different standards can be output at a time, support tester report personalized signature
· Built-in temperature collection, built-in water content detection, water activity collection, built-in viscosity detection wireless access to the office network, comes with unlimited database storage, customized standards unlimited addition of calibration curves unlimited additions

Zetron OPC-L3 Desktop Laser Oil Particle Counter Machine
Product Features

  1. Adopt the light blocking (shading) counting principle established by the International Hydraulic Standards Committee
  2. High-precision laser sensor with wide test range, stable performance, low noise and high resolution
  3. The high-pressure injection pump sampling method is adopted, the sampling volume can be set by yourself, the injection speed is stable, and the sampling accuracy is high
  4. The positive and negative pressure combined sampling system can achieve sample degassing, suitable for testing products with different viscosities
  5. Built-in pressure sensor, you can directly set the pressure value and automatically determine the air pressure in the cabin to ensure safety
  6. Built-in air purification system to ensure the test is not contaminated
  7. Built-in SAE4059E, SAE4059F, SAE4059F-CPC, NAS1638, ISO4406, GB/T14039, GJB-420A, GJB-420B, ГOCT17216-71, DL/T1096, SAE749D, JBT9737.1, QC/T29104-201, DL-T432-2018, HH005-2018 and other commonly used standards. It supports adding custom standard tests at will and there is no upper limit on the number of custom standards added. The required standards can be set according to customer needs.
  8. Built-in data analysis system, one test can provide all standard test data and contamination levels
  9. Built-in multiple calibration curves, compatible with all commonly used domestic and international standards, for single-channel or multi-channel fully automatic calibration
  10. The particle size can be set arbitrarily, and nearly 10,000 particle sizes are built-in to facilitate particle size analysis
  11. A variety of sampling containers such as standard sampling bottles or sampling cups can be used to meet the testing requirements of different industries
  12. Optional viscosity, dielectric constant, moisture and temperature sensor modules to achieve multi-parameter testing
  13. Windows operation interface, built-in database, unlimited data storage, can be used for retrieval and query by test standard, sample name, sample batch number, tester, test time, etc.
  14. Multi-level account authority management, account authority can be set separately, and digital signature is supported
  15. One control system supports multiple sensor settings, and the system control software can be installed on a tablet, laptop or desktop computer
  16. The test results can be printed using a micro or desktop printer, exported to PDF, Excel and other formats, and can be transmitted via USB, WiFi, etc.

 

Zetron OPC-L3 Desktop Laser Oil Particle Counter Machine
Zetron OPC-L3 Desktop Laser Oil Particle Counter Machine

Zetron OPC-L3 Desktop Laser Oil Particle Counter MachineZetron OPC-L3 Desktop Laser Oil Particle Counter Machine

Product Parameters

 

Model

OPC-L3

Light source

Semiconductor laser

Particle size range

0.8μm~600μm (calibrated according to 1~100um or 4~70um(c))

Detection channels

64 channels (Editable channels), the particle size can be set by the user

Sensitivity

0.8μm (ISO4402) or 3μm(c) (GB/T18854, ISO11171)

Resolution

<10% (GB/T18854, ISO11171)

Repeatability

RSD<2%

Sample detection viscosity

≤650cSt (viscosity is too large can be combined with heating or dilution method detection)

Sampling volume

0.2~6000mL, interval 0.1mL

Sampling accuracy

better than ± 0.5%

Sampling speed

5 ~80mL/min

Pneumatic chamber

Positive and negative air pressure chamber device, to realize sample degassing and high viscosity sample detection

Maximum vacuum of air 
pressure chamber

-0.08Mpa

Maximum positive pressure of 
air pressure chamber

0.8 Mpa

Maximum particle concentration

12000~40000 particles/mL

Power supply

110~245V AC, 50Hz, 70W

Overall Dimension

340mm×310mm×730mm

Net weight

22kg



Optional Functions
 

Temperature acquisition(optional)

-40~100ºC , Accuracy: ±0.5ºC

Moisture(optional)

Water activity collection: 1~100%RH; Accuracy: ±1%RH

Absolute water content(optional)

 1~ 360ppm ; Accuracy: ±10ppm

Dielectric constant(optional)

1~6

Viscosity(optional)

0~50 0cSt Accuracy: ±2%


 

Application


OPC-L3 Oil Particle Counter is applicable to the detection of particle contamination of hydraulic oil, lubricating oil, anti-fuel oil, insulating oil and turbine oil. It can be widely used in aviation, aerospace, electric power, petroleum, chemical industry, transportation, port, metallurgy, machinery, automobile manufacturing and other fields.

Zetron OPC-L3 Desktop Laser Oil Particle Counter Machine

Company Profile

Beijing Zetron Technology Co., Ltd, formerly Beijing Senre Technology Co., Ltd was founded in 2011, located in Beijing with convenient transportation access. We have almost 10 years experience in the retail, import and export of gas detection and monitoring equipment. This experience has enabled us to form an organization based on knowledge and expertise and have allowed us to supply a range of gas detectors and monitors that are tailored to our customers needs and budgets.
Our aim is to provide the best values products with high quality and style.To provide the new affordable and complete service for gas detection needs for the industrial, engineering and shipping market and our friendly staff are here to help with advice and prices.

Zetron OPC-L3 Desktop Laser Oil Particle Counter Machine

So far, we have customers/buyers from over 20 countries/regions like Bulgaria, Brazil, Canada, China, Colombia, Germany, Iraq, Japan, Philippines, Russian Federation, Singapore, Taiwan, Thailand, Uruguay, United States, Ukraine, Vietnam, etc.
The list of countries still expanding.....

We are committed to become the International Well Know Provider to provide similar or better alternative, original merchandises & service to meet customers' needs, requirements and solutions.
Every customer is important to us and we strive to satisfy all our Customers needs and expectations.

Zetron OPC-L3 Desktop Laser Oil Particle Counter Machine
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier