Zetron Mic600 Fixed Gas Analyzer 6 in 1 for Carbon Monoxide, Chlorine, Nitrogen Dioxide and Phosgene Gas Leakage Detector

Product Details
Customization: Available
After-sales Service: We Provide After Sale Services.
Warranty: 1 Year
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 4 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (15)
  • Zetron Mic600 Fixed Gas Analyzer 6 in 1 for Carbon Monoxide, Chlorine, Nitrogen Dioxide and Phosgene Gas Leakage Detector
  • Zetron Mic600 Fixed Gas Analyzer 6 in 1 for Carbon Monoxide, Chlorine, Nitrogen Dioxide and Phosgene Gas Leakage Detector
  • Zetron Mic600 Fixed Gas Analyzer 6 in 1 for Carbon Monoxide, Chlorine, Nitrogen Dioxide and Phosgene Gas Leakage Detector
  • Zetron Mic600 Fixed Gas Analyzer 6 in 1 for Carbon Monoxide, Chlorine, Nitrogen Dioxide and Phosgene Gas Leakage Detector
  • Zetron Mic600 Fixed Gas Analyzer 6 in 1 for Carbon Monoxide, Chlorine, Nitrogen Dioxide and Phosgene Gas Leakage Detector
  • Zetron Mic600 Fixed Gas Analyzer 6 in 1 for Carbon Monoxide, Chlorine, Nitrogen Dioxide and Phosgene Gas Leakage Detector
Find Similar Products
  • Overview
  • Specification
  • DETECTABLE GASES
  • Company Profile
Overview

Basic Info.

Model NO.
MIC600
Brand
Zetron
Customized
Customized
Portable
Non Portable
Certification
FCC, CE, RoHS, Atex
Gas
Can Be Customized
Type
Thermal Conductivity Gas Analyzer
Detecting Gas
Combustible Gas/H2s/Co/O2
Certificate
ISO9001 Cnex CE Atex
Response Time
T90<20s
Sampling Method
Depending on Gas Nature
Degree of Protection
IP67
Range
0 - 10/100/1000ppm/1%/25%
Working Voltage
24V
Recovery Time
<30s
Alarm Type
Multiple Alarm Mode
Sensor
Imported Highly Precise Sensor
Weight
1.78kg
Accuracy
3% F.S Can Be Customized
Linearity
3% F.S Can Be Customized
Resolution
0.01ppm, 0.01%Lel, 0.01%Vol
Diplay
1.7" HD LCD Display
Transport Package
Paper Carton
Specification
Highly Sensitive Imported Sensor
Trademark
Zetron
Origin
China
HS Code
902710
Production Capacity
1000/Month

Product Description

ZETRON MIC600 Fixed Gas Analyzer 6 in 1 for H2S NH3 SO2
The optional high-temperature high-humidity pretreatment system will be possible to detect the smoke gas at the temperature of1300 ºC. The detection for the gases at other temperatures can be customized. Simultaneously display the concentrations of multiple types of gases, repeatedly display the concentration of single-channel gases in large font, and display the realtime curve.2.5-inch high-definition color screen, display the information such as real-time concentration, alarm, time, temperature, humidity, storage, and so on; the menu interface adopted high definition simulation graphics to display the function name of each menu.
 
Standard configuration is the data storage capacity for 100, 000 entries; SD card storage function is optional configuration, real-time storage and fixed time storage are supported, or only the data of the alarm concentration will be stored; it is supported to use the local host to view, and delete data, and upload the data via RS485 interface to the computer for data analysis or printing.
 
It is possible for the real-time monitoring via the wired or remote wireless transmission, and network transmission; three-wire system 4 ~ 20mA standard signal and standard bus RS485 (modbus-RTU) simultaneous output; it is compatible with secondary instrument, data acquisition module, PLC,DCS system, and it is possible to drive the related equipment. Data recovery function; in case of mis-operation, it is possible to select partial or full recovery. Multiple alarm modes, and multi-directional and three-dimensional indication alarm states. It includes: 2 sets of relay switch output, sound & light alarm (optional configuration). Alarm types include: concentration alarm, and failure alarm.
Zetron Mic600 Fixed Gas Analyzer 6 in 1 for Carbon Monoxide, Chlorine, Nitrogen Dioxide and Phosgene Gas Leakage DetectorZetron Mic600 Fixed Gas Analyzer 6 in 1 for Carbon Monoxide, Chlorine, Nitrogen Dioxide and Phosgene Gas Leakage DetectorZetron Mic600 Fixed Gas Analyzer 6 in 1 for Carbon Monoxide, Chlorine, Nitrogen Dioxide and Phosgene Gas Leakage DetectorZetron Mic600 Fixed Gas Analyzer 6 in 1 for Carbon Monoxide, Chlorine, Nitrogen Dioxide and Phosgene Gas Leakage Detector
Specification
Type
Fixed Gas Detector
Detection range
0~ 10ppm
0~ 20ppm
0~50ppm
0~100ppm
Other ranges can be customized
Resolution
0.01ppm or 0.001ppm (0 ~ 10 ppm); 0.01ppm (0 ~ 100 ppm), 
Other ranges can be customized
Detection principle
Electrochemical, infrared, thermal conductivity, PID photoionization, and so on. Depending on the type of gas, range, field environment and user demand, Sensor can be customized
Sensor service life
Electrochemical principle: 2 ~ 3 years; Infrared principle: 5 ~ 10 years;
Thermal conductivity: 5 years
Allowable error
≤±2% F.S (other or higher precision levels can be customized)
Linearity
≤±2%
Repeatability
≤±2%
Uncertainty
≤±2%
Response time
T90≤30 seconds
Recovery time
≤30 seconds
Working environment
Temperature: -40 ºC ~ + 70 ºC, humidity: ≤10 ~ 95% RH (regular)
Working voltage
12 ~ 30VDC direct current the standard power supply for a single equipment is 24V, DC stabilized voltage switching power supply of 1A or greater than 1A
Power supply reference
24V, 2.1A is possible to drive 40 units of toxic gas detector, or 15 units of flammable, infrared gas detector.
Working method
Fixed type installation, online detection, diffusion type measurement
Protection level
IP66
Explosion-proof mark
ExdIICT6, certificate number: CNEx15.1283
Exterior dimensions
210×170×85mm (L×H×W)
Weight
1.8 Kg
Standard accessories
Manual, qualification certificate, warranty card, outer packaging box
DETECTABLE GASES
Detected Gases
Range
Minimum Reading
Detected Gases
Range
Minimum Reading
VOCs(VOC)
0-20ppm
0.01ppm
Ethylene oxide (ETO)
0- 100%LEL
0. 1%LEL
VOCs(VOC)
0-200ppm
0. 1ppm
Phosgene(COCL2)
0- 1ppm
0.001ppm
VOCs(VOC)
0-2000ppm
1ppm
Phosgene(COCL2)
0- 10ppm
0.01ppm
VOCs(VOC)
0- 10000ppm
1ppm
Silane(SiH4)
0- 1ppm
0.001ppm
Gas (EX)
0- 1000ppm
1ppm
Silane(SiH4)
0-50ppm
0.01ppm
Gas (EX)
0- 100%LEL
0. 1%LEL
Fluorine gas (F2)
0- 1ppm
0.001ppm
Gas (EX)
0- 100%VOL
0.01%VOL
Fluorine gas (F2)
0- 10ppm
0.001ppm
Methane (CH4)
0- 100%LEL
0. 1%LEL
Fluorine gas(F2)
0- 100ppm
0.01ppm
Methane (CH4)
0- 100%VOL
0.01%VOL
Hydrogen Fluoride (HF)
0- 10ppm
0.01ppm
Oxygen (O2)
0-30%VOL
0.01%VOL
Hydrogen Fluoride (HF)
0-50ppm
0.01ppm
Oxygen (O2)
0- 100%VOL
0.01%VOL
Hydrogen Bromide(HBr)
0-50ppm
0.01ppm
Carbon Monoxide (CO)
0- 100ppm
0.01ppm
Ethylborane(B2H6)
0- 10ppm
0.001ppm
Carbon Monoxide (CO)
0- 1000ppm
0. 1ppm
Arsine(AsH3)
0- 1ppm
0.001ppm
Carbon Monoxide (CO)
0-2000ppm
1ppm
Arsine(AsH3)
0- 10ppm
0.001ppm
Carbon Monoxide (CO)
0-5000ppm
1ppm
Germanium(GeH4)
0- 1ppm
0.001ppm
Carbon Monoxide (CO)
0- 10000ppm
1ppm
Germanium(GeH4)
0- 10ppm
0.001ppm
Carbon dioxide (CO2)
0-5000ppm
1ppm
Germanium(GeH4)
0-50ppm
0.01ppm
Carbon dioxide (CO2)
0-50000ppm
1ppm
Hydrazine, hydrazine hydrazide (N2H4)
0- 1ppm
0.001ppm
Carbon dioxide (CO2)
0-5%VOL
0.01%VOL
Hydrazine, hydrazine hydrazide (N2H4)
0-300ppm
0. 1ppm
Carbon dioxide (CO2)
0-20%VOL
0.01%VOL
Tetrahydrothiophene (THT)
0-50mg/m3
0.01 mg/m3
Carbon dioxide (CO2)
0- 100%VOL
0.01%VOL
Bromine (Br2)
0- 10ppm
0.01ppm
Formaldehyde (CH2O)
0- 10ppm
0.01ppm
Bromine gas (Br2)
0-50ppm
0.01ppm
Formaldehyde (CH2O)
0-50ppm
0.01ppm
Sulfur dioxide (SO2)
0-20ppm
0.01ppm
Formaldehyde (CH2O)
0- 100ppm
0.01ppm
Sulfur dioxide (SO2)
0- 100ppm
0.01ppm
Formaldehyde (CH2O)
0- 1000ppm
1ppm
Sulfur Dioxide(SO2)
0- 1000ppm
0. 1ppm
Ozone (O3)
0- 1ppm
0.001ppm
Sulfur dioxide (SO2)
0-5000ppm
1ppm
Ozone (O3)
0- 10ppm
0.01ppm
Nitric oxide (NO)
0-20ppm
0.01ppm
Ozone (O3)
0- 100ppm
0.01ppm
Nitric Oxide (NO)
0- 100ppm
0.01ppm
Ozone (O3)
0-2000ppm
1ppm
Nitric Oxide (NO)
0- 1000ppm
0. 1ppm
Hydrogen Sulfide (H2S)
0- 10ppm
0.01ppm
Nitric Oxide (NO)
0-5000ppm
1ppm
Hydrogen sulfide (H2S)
0- 100ppm
0.01ppm
Nitrogen Dioxide (NO2)
0-20ppm
0.01ppm
Hydrogen sulfide (H2S)
0-500ppm
0. 1ppm
Nitrogen dioxide
0- 100ppm
0.01ppm
Hydrogen sulfide (H2S)
0-2000ppm
1ppm
Nitrogen dioxide
0- 1000ppm
0. 1ppm
Hydrogen Cyanide(HCN)
0- 100ppm
0.01ppm
Nitrogen Dioxide (NO2)
0-2000ppm
1ppm
Hydrogen Chloride(HCL)
0-20ppm
0.01ppm
Nitrogen Oxides (NOX)
0- 100ppm
0.01ppm
Hydrogen chloride (HCL)
0-200ppm
0. 1ppm
Nitrogen Oxides (NOX)
0-500ppm
0. 1ppm
Phosphine (PH3)
0-5 ppm
0.001ppm
Nitrogen oxides (NOX)
0-2000ppm
1ppm
Phosphine (PH3)
0-20 ppm
0.01ppm
Chlorine (CL2)
0-20ppm
0.01ppm
Phosphine(PH3)
0-2000 ppm
1ppm
Chlorine (CL2)
0-200ppm
0. 1ppm
Chlorine dioxide (CLO2)
0- 1ppm
0.001ppm
Ammonia (NH3)
0- 10ppm
0.01ppm
Chlorine dioxide (CLO2)
0- 10ppm
0.01ppm
Ammonia (NH3)
0- 100ppm
0.01ppm
Chlorine dioxide (CLO2)
0- 100ppm
0.01ppm
Ammonia(NH3)
0- 1000ppm
0. 1ppm
Ethylene oxide (ETO)
0- 100ppm
0.01ppm
Ammonia gas (NH3)
0-5000ppm
1ppm
Ethylene oxide (ETO)
0- 1000ppm
0. 1ppm
Ammonia(NH3)
0- 100%LEL
0. 1%LEL
Note: Not all gases and range are listed, if you need more information, please contact us.

Zetron Mic600 Fixed Gas Analyzer 6 in 1 for Carbon Monoxide, Chlorine, Nitrogen Dioxide and Phosgene Gas Leakage DetectorZetron Mic600 Fixed Gas Analyzer 6 in 1 for Carbon Monoxide, Chlorine, Nitrogen Dioxide and Phosgene Gas Leakage Detector
Company Profile

Beijing Zetron Technology Co., Ltd, With 20 years combined experience, Zetron develops, manufacture and market a complete range of gas detection equipment to protect people from hazardous conditions in the industry, research and commercial applications. Today Zetron is in providing gas detection equipment, services and solutions to keep your personnel and plant safe. Our complete product range includes portable gas detector, fixed detection systems, landfill gas analyzer, remote laser methane gas detector, as well as air quality monitoring systems.
As part of our focus on quality, Zetron is ISO9001:2005 and SGS certified and our products have acquired the CE, RoHS, FCC, and ATEX certifications.
So far, we have customers/buyers from over 20 countries/regions like Bulgaria, Brazil, Canada, China, Colombia, Germany, Iraq, Japan, Philippines, Russian Federation, Singapore, Taiwan, Thailand, Uruguay, United States, Ukraine, Vietnam, etc.
The list of countries still expanding.....

We are committed to become the International Well Know Provider to provide similar or better alternative, original merchandises & service to meet customers' needs, requirements and solutions.
Every customer is important to us and we strive to satisfy all our Customers needs and expectations.

Zetron Mic600 Fixed Gas Analyzer 6 in 1 for Carbon Monoxide, Chlorine, Nitrogen Dioxide and Phosgene Gas Leakage Detector
Zetron Mic600 Fixed Gas Analyzer 6 in 1 for Carbon Monoxide, Chlorine, Nitrogen Dioxide and Phosgene Gas Leakage Detector

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier