Zetron Ms104K Portable 4 in 1 Gas Detector for C6h6 C7h8 C8h10 Pid

Product Details
Customization: Available
After-sales Service: We Provide After Sale Services.
Warranty: 1 Year
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 4 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (15)
  • Zetron Ms104K Portable 4 in 1 Gas Detector for C6h6 C7h8 C8h10 Pid
  • Zetron Ms104K Portable 4 in 1 Gas Detector for C6h6 C7h8 C8h10 Pid
  • Zetron Ms104K Portable 4 in 1 Gas Detector for C6h6 C7h8 C8h10 Pid
  • Zetron Ms104K Portable 4 in 1 Gas Detector for C6h6 C7h8 C8h10 Pid
  • Zetron Ms104K Portable 4 in 1 Gas Detector for C6h6 C7h8 C8h10 Pid
  • Zetron Ms104K Portable 4 in 1 Gas Detector for C6h6 C7h8 C8h10 Pid
Find Similar Products
  • Overview
  • Specification
  • Detailed Photos
  • DETECTABLE GASES
  • Company Profile
Overview

Basic Info.

Model NO.
MS104K
Brand
Zetron
Customized
Customized
Portable
Portable
Certification
FCC, CE, RoHS
Gas
4 Types of Gasses Can Be Customized
Type
Electrochemical Catalytic Infrared and Pid
Sensor
Imported Highly Sensitive Sensor
Alarm
Sound+Vibration+Light
Degree of Protection
IP65
Response Time
T90<20s
Sampling Method
Diffusion Type Sampling
Working Temperature
Standard -20~50c (Can Be Customized)
Humidity
<95%Rh
Display
2.31" HD Color LCD Display
Measuring Range
Vol% Lel %
Resolution
0.01% Vol, 0.01% Lel
Sensor Life
Can Be Customized
Power Supply
3.7VDC, 3000mahhigh Capacity Rechargeable Polymer
Weight
200g
Explosion-Proof Mark
Exia II CT6
Exterior Dimensions
130X68X34mm (Lxwxh)
Transport Package
Paper Carton
Specification
Built in Suction Pump 4 in 1 Multi Gas Detector
Trademark
Zetron
Origin
China
HS Code
902710
Production Capacity
10000/Month

Product Description

Zetron MS104K Portable Multi Gas Detector

It can be used in: rapid detection of a variety of gas concentration and measurement of environmental temperature and humidity, if the measurement exceeded the limit value, the alarm will emit sound & light vibration as alarm. Adopted 2.31-inch high-definition color screen for real-time display, adopted the gas sensors of industrially well-known brands.
 
The main detection principles include: electrochemical, infrared, catalytic combustion, thermal conductivity, PID photoionization, and so on. Advanced electric circuit design, mature kernel algorithm processing, unique external appearance design, had achieved a number of patents about the software works, external appearance, and so on. 
 
Suitable for detecting the concentrations of gases in the atmosphere environment in the pipeline or confined space. The purity of the gas leakage and various high concentration single gases with the background gas as nitrogen gas or oxygen gas. The types of gases for detection are more than 500 types.
 
Specification
 
Gases to be detected
 Arbitrary combination of 1 ~ 4 types of gases such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on. Optional configuration: temperature and humidity measurements.
Application scenarios
All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.
Detection range
0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 100%LEL, 20%, 50%, 100%Vol, can be selected; and other ranges can be customized.
Resolution
0.01ppm or 0.001ppm (0 ~ 10 ppm);
0.01ppm (0 ~ 100 ppm),
0.1ppm (0 ~ 1000 ppm),
1ppm (0 ~ 10000 ppm or more),
0.01 mg/l (0 ~ 200 mg/l),
0.1% LEL,
0.01%,
0.001% Vol
Detection principle
Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of gas, range, field environment and user demand.
Sensor service life
Electrochemical principle: 2 ~ 3 years; Oxygen gas: 2 years or 6 years can be selected; infrared principle: 5 ~ 10 years;
catalytic combustion: 3 years; thermal conductivity: 5 years; PID photoionization: 2 ~ 3 years.
Allowable error
≤±3% F.S (higher precision levels can be customized)
Linearity
≤±2%
Repeatability
≤±2%
Uncertainty
≤±2%
Response time
T90≤30 seconds
Recovery time
≤30 seconds
Working environment
Temperature: -40 ºC ~ + 70 ºC, humidity: ≤10 ~ 95% RH
Sample gas temperature
-40 ºC ~ + 70 ºC, and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect
the smoke gas at the temperature of 400 ºC or higher.
Temperature and humidity measurement
Optional configuration: temperature at -40 ºC ~ + 70 ºC, accuracy level at 0.5 ºC; humidity at 0 ~ 100% RH, precision level at 3 % RH
Power supply
3.7VDC, 3000mA high capacity rechargeable polymer battery
Display mode
2.31-inch high-definition color screen
Detection mode
Diffusion type measurement. The calibrated flow rate is 500 ml/minute.
Alarm mode
It is possible to set as sound & light alarm, vibration alarm, sound & light + vibration alarm, turning off the alarm.
Communication interface
USB (charging and communication), optional: RS485 communication interface
Data storage
Standard configuration is the data storage capacity for 100, 000 entries
Protection level
IP65
Explosion-proof type
Intrinsically safe type
Explosion-proof mark
Exia II CT4 Ga
Exterior dimensions
130×68×34mm (L×W×H)
Weight
200g
Standard accessories
Manual, qualification certificate, warranty card, USB charger (including the data cable), belt clip, colorful packaging box (optional high-grade aluminum instrument case)
Optional items
Temperature and humidity measurement function, external gas sampling pump, 1.2 m retractable sampling handle (1-10 meter hose, and
the standard length is 1 meter), 0.4 meter stainless steel sampling handle (with dust filter, not retractable)
 
 
Detailed Photos
 

Zetron Ms104K Portable 4 in 1 Gas Detector for C6h6 C7h8 C8h10 PidZetron Ms104K Portable 4 in 1 Gas Detector for C6h6 C7h8 C8h10 PidZetron Ms104K Portable 4 in 1 Gas Detector for C6h6 C7h8 C8h10 PidZetron Ms104K Portable 4 in 1 Gas Detector for C6h6 C7h8 C8h10 PidZetron Ms104K Portable 4 in 1 Gas Detector for C6h6 C7h8 C8h10 Pid

Zetron Ms104K Portable 4 in 1 Gas Detector for C6h6 C7h8 C8h10 PidZetron Ms104K Portable 4 in 1 Gas Detector for C6h6 C7h8 C8h10 Pid
DETECTABLE GASES
 
Note: please call us to consult about other gases and other detection range which are not listed in the above table.
Gases
Range
Allowable Error 
Minimum reading
Response time T90
Combustible gas ( EX )
0-100%LEL
<±3%(F.S)
0.1%LEL
≤10 seconds
Combustible gas ( EX )
0-100%Vol
<±3%(F.S)
0.1%Vol
≤10 seconds
Methane ( CH4 )
0-100%LEL
<±3%(F.S)
0.1%LEL
≤10 seconds
Methane ( CH4 )
0-100%Vol
<±3%(F.S)
0.1%Vol
≤10 seconds
Oxygen gas ( O2 )
0-30%Vol
<±3%(F.S)
0.01%Vol
≤10 seconds
Oxygen gas ( O2 )
0-100%Vol
<±3%(F.S)
0.01%Vol
≤10 seconds
Oxygen gas ( O2 )
0-5000ppm
<±3%(F.S)
1ppm
≤30 seconds
Nitrogen gas ( N2 )
0-100%Vol
<±3%(F.S)
0.01%Vol
≤10 seconds
Carbon monoxide ( CO )
0-100ppm
<±3%(F.S)
0.1ppm
≤25 seconds
Carbon monoxide ( CO )
0-1000ppm
<±3%(F.S)
0.1ppm
≤25 seconds
Carbon monoxide ( CO )
0-2000ppm
<±3%(F.S)
0.1ppm
≤25 seconds
Carbon monoxide ( CO )
0-20000ppm
<±3%(F.S)
1ppm
≤25 seconds
Carbon monoxide ( CO )
0-100000ppm
<±3%(F.S)
1ppm
≤25 seconds
Carbon dioxide ( CO2 )
0-500ppm
<±3%(F.S)
1ppm
≤20 seconds
Carbon dioxide ( CO2 )
0-2000ppm
<±3%(F.S)
1ppm
≤20 seconds
Carbon dioxide ( CO2 )
0-5000ppm
<±3%(F.S)
1ppm
≤20 seconds
Carbon dioxide ( CO2 )
0-50000ppm
<±3%(F.S)
1ppm
≤30 seconds
Carbon dioxide ( CO2 )
0-20%Vol
<±3%(F.S)
0.01%Vol
≤30 seconds
Carbon dioxide ( CO2 )
0-100%Vol
<±3%(F.S)
0.01%Vol
≤30 seconds
Formaldehyde ( CH2O )
0-10ppm
<±3%(F.S)
0.001ppm
≤30 seconds
Formaldehyde ( CH2O )
0-10ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Formaldehyde ( CH2O )
0-100ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Formaldehyde ( CH2O )
0-5000ppm
<±3%(F.S)
1ppm
≤50 seconds
Ozone ( O3 )
0-1ppm
<±3%(F.S)
0.001ppm
≤20 seconds
Ozone ( O3 )
0-5ppm
<±3%(F.S)
0.001ppm
≤20 seconds
Ozone ( O3 )
0-50ppm
<±3%(F.S)
0.01ppm
≤20 seconds
Ozone ( O3 )
0-100ppm
<±3%(F.S)
0.01ppm
≤20 seconds
Ozone ( O3 )
0-2000ppm
<±3%(F.S)
0.1ppm
≤30 seconds
Ozone ( O3 )
0-30000ppm
<±3%(F.S)
1ppm
≤30 seconds
Ozone ( O3 )
0-20mg/L
<±3%(F.S)
0.01mg/L
≤30 seconds
Ozone water ( O3 )
0-20mg/L
<±3%(F.S)
0.01mg/L
≤30 seconds
Hydrogen sulfide ( H2S )
0-10ppm
<±3%(F.S)
0.001ppm
≤30 seconds
Hydrogen sulfide ( H2S )
0-50ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Hydrogen sulfide ( H2S )
0-100ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Hydrogen sulfide ( H2S )
0-2000ppm
<±3%(F.S)
0.1ppm
≤30 seconds
Hydrogen sulfide ( H2S )
0-10000ppm
<±3%(F.S)
1ppm
≤45 seconds
Sulfur dioxide ( SO2 )
0-10ppm
<±3%(F.S)
0.001ppm
≤30 seconds
Sulfur dioxide ( SO2 )
0-20ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Sulfur dioxide ( SO2 )
0-100ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Sulfur dioxide ( SO2 )
0-500ppm
<±3%(F.S)
0.1ppm
≤30 seconds
Sulfur dioxide ( SO2 )
0-2000ppm
<±3%(F.S)
0.1ppm
≤30 seconds
Sulfur dioxide ( SO2 )
0-10000ppm
<±3%(F.S)
1ppm
≤30 seconds
Nitric oxide ( NO )
0-10ppm
<±3%(F.S)
0.001ppm
≤30 seconds
Nitric oxide ( NO )
0-100ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Nitric oxide ( NO )
0-2000ppm
<±3%(F.S)
0.1ppm
≤30 seconds
Nitric oxide ( NO )
0-5000ppm
<±3%(F.S)
1ppm
≤30 seconds
Nitrogen dioxide ( NO2 )
0-10ppm
<±3%(F.S)
0.001ppm
≤25 seconds
Nitrogen dioxide ( NO2 )
0-100ppm
<±3%(F.S)
0.01ppm
≤25 seconds
Nitrogen dioxide ( NO2 )
0-1000ppm
<±3%(F.S)
0.1ppm
≤30 seconds
Nitrogen dioxide ( NO2 )
0-5000ppm
<±3%(F.S)
1ppm
≤30 seconds
Nitrogen oxide ( NOX )
0-10ppm
<±3%(F.S)
0.001ppm
≤30 seconds
Nitrogen oxide ( NOX )
0-100ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Nitrogen oxide ( NOX )
0-2000ppm
<±3%(F.S)
0.1ppm
≤30 seconds
Nitrogen oxide ( NOX )
0-5000ppm
<±3%(F.S)
1ppm
≤30 seconds
Chlorine gas ( CL2 )
0-10ppm
<±3%(F.S)
0.001ppm
≤30 seconds
Chlorine gas ( CL2 )
0-20ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Chlorine gas ( CL2 )
0-200ppm
<±3%(F.S)
0.1ppm
≤30 seconds
Chlorine gas ( CL2 )
0-2000ppm
<±3%(F.S)
0.1ppm
≤30 seconds
Ammonia gas ( NH3 )
0-50ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Ammonia gas ( NH3 )
0-100ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Ammonia gas ( NH3 )
0-1000ppm
<±3%(F.S)
0.1ppm
≤30 seconds
Ammonia gas ( NH3 )
0-5000ppm
<±3%(F.S)
1ppm
≤30 seconds
Ammonia gas ( NH3 )
0-100%LEL
<±3%(F.S)
0.1%LEL
≤10 seconds
Hydrogen gas ( H2 )
0-100%LEL
<±3%(F.S)
0.1%LEL
≤10 seconds
Hydrogen gas ( H2 )
0-1000ppm
<±3%(F.S)
0.1ppm
≤30 seconds
Hydrogen gas ( H2 )
0-20000ppm
<±3%(F.S)
1ppm
≤30 seconds
Hydrogen gas ( H2 )
0-40000ppm
<±3%(F.S)
1ppm
≤30 seconds
Hydrogen gas ( H2 )
0-100%Vol
<±3%(F.S)
0.01%Vol
≤20 seconds
Helium gas ( He )
0-100%Vol
<±3%(F.S)
0.01%Vol
≤20 seconds
Argon gas ( Ar )
0-100%Vol
<±3%(F.S)
0.01%Vol
≤20 seconds
Xenon gas ( Xe )
0-100%Vol
<±3%(F.S)
0.01%Vol
≤20 seconds
Hydrogen cyanide ( HCN )
0-30ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Hydrogen cyanide ( HCN )
0-100ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Hydrogen chloride ( HCL )
0-20ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Hydrogen chloride ( HCL )
0-200ppm
<±3%(F.S)
0.1ppm
≤30 seconds
Phosphorus hydride ( PH3 )
0-5 ppm
<±3%(F.S)
0.001ppm
≤30 seconds
Phosphorus hydride ( PH3 )
0-25 ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Phosphorus hydride ( PH3 )
0-2000 ppm
<±3%(F.S)
1ppm
≤30 seconds
Chlorine dioxide ( CL O2 )
0-1ppm
<±3%(F.S)
0.001ppm
≤30 seconds
Chlorine dioxide ( CL O2 )
0-10ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Chlorine dioxide ( CL O2 )
0-200ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Ethylene oxide ( ETO )
0-100ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Ethylene oxide ( ETO )
0-1000ppm
<±3%(F.S)
0.1ppm
≤30 seconds
Ethylene oxide ( ETO )
0-100%LEL
<±3%(F.S)
1%LEL
≤30 seconds
Phosgene ( COCL2 )
0-1ppm
<±3%(F.S)
0.001ppm
≤20 seconds
Phosgene ( COCL2 )
0-50ppm
<±3%(F.S)
0.01ppm
≤20 seconds
Silane ( SiH4 )
0-1ppm
<±3%(F.S)
0.001ppm
≤30 seconds
Silane ( SiH4 )
0-50ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Fluorine gas ( F2 )
0-1ppm
<±3%(F.S)
0.001ppm
≤30 seconds
Fluorine gas ( F2 )
0-10ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Fluorine gas ( F2 )
0-50ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Hydrogen fluoride ( HF )
0-10ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Hydrogen fluoride ( HF )
0-50ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Hydrogen bromide ( HBr )
0-50ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Diborane ( B2H6 )
0-10ppm
<±3%(F.S)
0.001ppm
≤30 seconds
Arseniuretted hydrogen 
( AsH3 )
0-1ppm
<±3%(F.S)
0.001ppm
≤30 seconds
Arseniuretted hydrogen
 ( AsH3 )
0-10ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Arseniuretted hydrogen 
( AsH3 )
0-50ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Germane ( GeH4 )
0-2ppm
<±3%(F.S)
0.001ppm
≤30 seconds
Germane ( GeH4 )
0-20ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Hydrazine ( N2H4 )
0-1ppm
<±3%(F.S)
0.001ppm
≤30 seconds
Hydrazine ( N2H4 )
0-300ppm
<±3%(F.S)
0.1ppm
≤30 seconds
Tetrahydrothiophene ( THT )
0-100mg/m3
<±3%(F.S)
0.01 mg/m3
≤60 seconds
Bromine gas ( Br2 )
0-10ppm
<±3%(F.S)
0.001ppm
≤30 seconds
Bromine gas ( Br2 )
0-100ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Bromine gas ( Br2 )
0-2000ppm
<±3%(F.S)
1ppm
≤30 seconds
Ethyne ( C2 H2 )
0-100%LEL
<±3%(F.S)
0.1%LEL
≤30 seconds
Ethyne ( C2 H2 )
0-100ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Ethyne ( C2 H2 )
0-1000ppm
<±3%(F.S)
0.1ppm
≤30 seconds
Ethylene ( C2 H4 )
0-100%LEL
<±3%(F.S)
0.1%LEL
≤30 seconds
Ethylene ( C2 H4 )
0-100ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Ethylene ( C2 H4 )
0-2000ppm
<±3%(F.S)
0.1ppm
≤30 seconds
Acetaldehyde
0-10ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Ethanol ( C2 H6O )
0-100ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Ethanol ( C2 H6O )
0-2000ppm
<±3%(F.S)
1ppm
≤30 seconds
Methanol ( CH6O )
0-100ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Methanol ( CH6O )
0-2000ppm
<±3%(F.S)
1ppm
≤30 seconds
Carbon disulfide ( CS2 )
0-50ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Carbon disulfide ( CS2 )
0-5000ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Acrylonitrile ( C3H3N )
0-50ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Acrylonitrile ( C3H3N )
0-2000ppm
<±3%(F.S)
1ppm
≤30 seconds
Methylamine ( CH5N )
0-50ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Iodine gas ( I2 )
0-50ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Styrene ( C8 H8 )
0-200ppm
<±3%(F.S)
0.1ppm
≤30 seconds
Styrene ( C8 H8 )
0-5000ppm
<±3%(F.S)
1ppm
≤30 seconds
Chloroethylene ( C2 H3CL )
0-100ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Trichloroethylene ( C2 HCL3 )
0-100ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Tetrachlorethylene ( C2 CL4 )
0-100ppm
<±3%(F.S)
0.01ppm
≤30 seconds
( N2 O )
0-100ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Nitrogen trifluoride ( NF3 )
0-100ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Hydrogen peroxide ( H2 O2 )
0-100ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Methyl bromide ( CH3 Br )
0-100ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Methyl bromide ( CH3 Br )
0-30000ppm
<±3%(F.S)
1ppm
≤30 seconds
Methyl bromide ( CH3 Br )
0-200g/m3
<±3%(F.S)
0.1g/m3
≤30 seconds
Sulfuryl fluoride ( SO2 F2 )
0-100ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Sulfuryl fluoride ( SO2 F2 )
0-5000ppm
<±3%(F.S)
1ppm
≤30 seconds
Sulfuryl fluoride ( SO2 F2 )
0-10000ppm
<±3%(F.S)
1ppm
≤30 seconds
Benzene ( C6 H6 )
0-10ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Benzene ( C6 H6 )
0-100ppm
<±3%(F.S)
0.01ppm
≤30 seconds
Benzene ( C6 H6 )
0-2000ppm
<±3%(F.S)
1ppm
≤30 seconds


 
Company Profile

Beijing Zetron Technology Co., Ltd, formerly Beijing Senre Technology Co., Ltd was founded in 2011, located in Beijing with convenient transportation access. We have almost 10 years experience in the retail, import and export of gas detection and monitoring equipment. This experience has enabled us to form an organization based on knowledge and expertise and have allowed us to supply a range of gas detectors and monitors that are tailored to our customers needs and budgets.
Our aim is to provide the best values products with high quality and style.To provide the new affordable and complete service for gas detection needs for the industrial, engineering and shipping market and our friendly staff are here to help with advice and prices.

Zetron Ms104K Portable 4 in 1 Gas Detector for C6h6 C7h8 C8h10 Pid

So far, we have customers/buyers from over 20 countries/regions like Bulgaria, Brazil, Canada, China, Colombia, Germany, Iraq, Japan, Philippines, Russian Federation, Singapore, Taiwan, Thailand, Uruguay, United States, Ukraine, Vietnam, etc.
The list of countries still expanding.....

We are committed to become the International Well Know Provider to provide similar or better alternative, original merchandises & service to meet customers' needs, requirements and solutions.
Every customer is important to us and we strive to satisfy all our Customers needs and expectations.


Zetron Ms104K Portable 4 in 1 Gas Detector for C6h6 C7h8 C8h10 Pid

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier