MIC600 Specifications | |
Size | 210×170×85mm (L×H×W) |
Weight | 1.8 Kg |
Response Time | T90≤20 seconds |
Allowable Error | ≤±2% F.S (higher precision levels can be customized) |
Data Storage | 100, 000 entries |
Ingress Protection | IP 66 |
Explosion-proof mark | Exd2CT6, certificate number: CNEx15.1283 |
Detection Range | Refer to Sensor Specifications (next page) |
Power Supply | The switching power supply of 24V, 2.1A is possible to drive 30 units of toxic gas detector, or 15 units of flammable, infrared gas detector . |
Working Environment | Temperature: -40 ºC ~ + 70 ºC Humidity: ≤10 ~ 95% RH (regular) non-condensing case It should be customized in the case of use in the condensing case, or the use environment should be specified at the time of ordering. Range of working pressure: atmospheric pressure ± 30%, some sensors can detect under the pressure of 7 kg . |
Alarms | The default option is 1-way, and it is possible to select 3- way passive contact (dry contact) output, level III alarm, and the alarm point can be set. Field sound & light alarm (optional configuration). |
Detection Principle | Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of gas, range, field environment and user demand. |
Signal Output | Bus system RS485 (RTU), three (four) wire system 4 ~ 20mA, optional configuration: 0 ~ 20mA, 1 ~ 5V, 0 ~ 5V, 0 ~ 10V, wireless transmission, network transmission, and SMS alarms. |
Installation method | Pipeline type, and wall mounting type. The working pressure of the pipeline type is ± 30% of atmospheric pressure, and when exceeded this range, it is necessary for the depressurization treatment. |
Connecting cable |
Adopted 4 ~ 20mA three-core shielding cable, adopted four-core for RS485, when the distance exceeded 100 meters, the single wire diameter ≥1.5mm; Both ends of the shielding layer will be connected to the ground, and good grounding should be ensured. |
Standard Accessories | Manual, qualification certificate, warranty card, outer packaging box |
Petroleum, chemical, pharmaceutical, environmental protection, gas distribution, flue gas analysis,air treatment and all other occasions that need to detect and analyze gas concentration.